Modified sine wave 240VAC UPS Power Inverter IG3110E Series 600VA, 900VA, 1400VA, 1800VA
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | 5PCS Solar Power Inverters | Price : | Negotiable Price |
---|---|---|---|
Packaging Details : | Standard Exported Cartons and Pallets For Solar Power Inverters | Delivery Time : | Within 15-30days after receiving your 30% TT deposit |
Payment Terms : | Western Union, L/C, T/T | Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000 | Model Number: | SSP3118C2 1- 5KVA |
Detail Information |
|||
Product Name: | Solar Power Inverter | Nominal Voltage: | 220/230VAC |
---|---|---|---|
Solar Controller: | MPPT Controller | Application: | PC,TV,DVD |
Wave Form: | Pure Sine Wave | Display: | LCD Display |
Output Power Factor: | 0.8 | Transfer Time: | 20ms |
Parallel Operation: | Up To 6 Units (only For 4K/5K) | ||
Highlight: | solar power inverter for home,solar energy inverter |
Product Description
1-5KVA Pure Sine Wave Wall Mounted Inverter Built-in MPPT Solar Charge Controller
SSP31182C2 Solar Inverter Product Description
it is Off-Grid Solar Power Inverter, output PF=0.8, LCD setting, Smart battery charger design, charge current and input voltage range optional. Built in 60A MPPT controller, remote panel available, often used for PC, TV, DVD, Solar inverter ect , Main characteristic is that parallel operation with up to 6 units only for 4KVA/5KVA.Single phase output up to 24kw using 6 units, three phase output using either 3 units (12kw) or max 6 units (24kw).
Parallel configuration (only SSP3118C 4KVA/5KVA)
Our products can be put in parallel configuration,up to 6 pieces parallel,if the necessary power is too high for a single unit.
SSP31182C2 Solar Inverter Key Features:
1.Hybrid Off-Grid Solar Power Inverters
2.Built-in MPPT solar controller
3.Support mains voltage or generator power
4.Auto restart while AC is recovering
5.6 units can Parallel operation only for 4Kva/5Kva
6.Cold start function,Remote panel available
7.Selectable charging current based on applications
8.Configurable AC/Solar input priority via LCD setting
9.Smart battery charger design for optimized battery performance
10.Selectable input voltage range for home appliances and personal computers
SSP31182C2 Solar Inverter Full protection:
1.Low battery voltage protection
2.Over load protection
3.Output short circuit
4.Over- temperature
5.Restrain surge interference
6.Eliminate noise protection for thunder striking,provide the reliable power to the home appliances.
Technical Specification of SSP3118C2 Series Solar Power Inverters:
MODEL | C2 1K-2425 | C2 2K-2425 | C2 3K-2425 | C2 4K-4880 | C2 5K-4880 | ||
Rated Power | 1KVA/800W | 2KVA/1600W | 3KVA/2.4KW | 4KVA/3.2KW | 5KVA/4KW | ||
INPUT | |||||||
Voltage | 230 VAC | ||||||
Selectable Voltage Range | 170-280 VAC (For Personal Computers) 90-280 VAC (For Home Appliances) | ||||||
Frequency Range | 50 Hz/60 Hz (Auto sensing) | ||||||
OUTPUT | |||||||
AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | ||||||
Surge Power | 2000VA | 4000VA | 6000VA | 8000VA | 10000VA | ||
Efficiency (Peak) | 90% | 93% | |||||
Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | ||||||
Waveform | Pure sine wave | ||||||
BATTERY | |||||||
Battery Voltage | 24 VDC | 48 VDC | |||||
Floating Charge Voltage | 27 VDC | 54 VDC | |||||
Overcharge Protection | 31 VDC | 60 VDC | |||||
SOLAR CHARGER & AC CHARGER | |||||||
Maximum PV Array Power | 600W | 600W | 4000W | ||||
MPPT Range @ Operating Voltage | 30 ~ 66VDC | 30 ~ 66VDC | 60VDC ~115VDC | ||||
Maximum PV Array Open Circuit Voltage | 75VDC | 75VDC | 145 VDC | ||||
Maximum Solar Charge Current | 25A | 25A | 80A | ||||
Maximum AC Charge Current | 20A | 30A | 30A | 60 A | |||
Maximum Charge Current | 25A | 30A | 30A | 140A | |||
AC charger and solar charger can’t work at the same time. | |||||||
Maximum Efficiency | 98% | ||||||
Standby Power Consumption | 2 W | ||||||
PHYSICAL | |||||||
Dimension, D x W x H (mm) | 105*272*355 | 120 x 295 x 468 | |||||
Net Weight (kgs) | 6.8 | 7.4 | 11.0 | ||||
OPERATING ENVIRONMENT | |||||||
Humidity | 5% to 95% Relative Humidity(Non-condensing) | ||||||
Operating Temperature | 0°C to 55°C | ||||||
Storage Temperature | -15°C to 60°C |
WHY CHOOSE US ? |
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
FAQ |
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
3. How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
4. How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................
Enter Your Message