Modified sine wave 240VAC UPS Power Inverter IG3110E Series 600VA, 900VA, 1400VA, 1800VA
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | 1PCS Inverter ( Sample Are Available) | Price : | Negotiable |
---|---|---|---|
Packaging Details : | Standard Exported Cartons and Pallets for solar power inverter system | Delivery Time : | Within 15-30days after receiving your 30% TT deposit |
Payment Terms : | Western Union, T/T, L/C | Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000 | Model Number: | SSP3111C 1-2KVA |
Detail Information |
|||
Product Name: | SSP3111C Inverter | Capacity: | 1-2KVA |
---|---|---|---|
Wave Form: | Modified Sine Wave Output | Power Factor: | 0.7 |
Solar Controller: | 40A PWM | Frequency: | 50/60hz |
Convertion: | DC /AC Inverters | Application: | Solar Power |
Color: | Red | Dispaly: | LCD&LED |
Nominal Voltage: | 230VAC | Battery Voltage: | 24v |
High Light: | solar energy inverter,home power inverter |
Product Description
220/230/240VAC Modified Sine Wave output 1-2KVA Solar Power Inverter System
Key Features
· Modified sine wave output;
· Built-in PWM solar charge controller;
· 1KVA and 2KVA are available;
· Selectable input voltage range for home appliances and personal computers;
· Selectable charging current based on applications;
· Auto restart while AC is recovering;
· Smart battery charger design to optimize battery performance;
Application
Supply the reliable long back up time power for the household appliances office appliances and solar power systems ect,
Product Description
1. Built-in PWM solar charge controller.
2.Modified sine wave output.
3.High frequency design.
4.Optional input voltage range.
5.Full automatic and silent operation.
6.Automatic transfer AC-DC.
7.Over-load protection.
8.Automatic restart.
9.Three-steps intelligent charging control to recharging.
10.LCD display audible and visual alarm.
Full Protection
Protection for low battery voltage,overload,output short circuit and over-temperature restrain surge interference.eliminate noise,provide the reliabie power to the household appliances.
SOROTEC SSP3111C
Model | SSP3111C 1-2KVA |
Nominal Voltage | 220/230/240VAC |
Nominal Frequency | 50/60HZ |
Output power factor | 0.7 |
Battery charge current | 15/20A(optional) |
Application | Solar power |
SSP3111C 1-2KVA Solar Inverter With PWM Solar Controller
Model | SSP3111C 1000-2000VA | ||
1000-12 | 2000-24 | ||
Capacity | 1000VA/720W | 2000VA/1300W | |
Nominal Voltage | 220/230/240VAC | ||
Nominal Frequency | 50/60HZ | ||
Input | |||
Voltage Range | 170-280VAC±4%(Narrow Range) 90VAC~280VAC±4%(Wide Range) | ||
Frequency Range | 50/60HZ | ||
Output | |||
Voltage Regulation | 230VAC±2% | ||
Frequency Regulation | 50/60Hz±0.1HZ | ||
Wave Form | Modified sine wave | ||
Utility battery mode | 15-20ms typical(narrow range);40ms max (wide range) | ||
Battery mode utility | 10ms max | ||
Battery mode | >80% | ||
Line mode | >95%(battery full charged) | ||
Battery | |||
DC VOLTAGE | 12V | 24V | |
Overcharge Protection | 16V | 32V | |
Charge Current | 15A/20A | 10A | |
LCD Display &LED Indicate | |||
Line mode | Line mode1,charge current >3A Green flashing every 2 seconds. | ||
Line mode1,charge current <=3A Green solid lighting | |||
Off-charge mode | |||
Battery mode | Yellow lighting | ||
Overload | Red flashing every 0.5 second | ||
Fault | Red lighting | ||
Solar charger | |||
Maximum PV array open circuit voltage | 55VDC | ||
PV Optimal work voltage | 15-18Vdc | 30-36Vdc | |
Maximum charging current | 40A | ||
Maximum Efficiency | >96% | ||
Standby Power consumption | <20W | ||
Environment | |||
Temperature | 0℃-40℃ | ||
Humidity | 5%-95%(<40℃,Non-condensing) | ||
Storage Temperature | ~15℃~55℃ | ||
Elevation | <1500M | ||
IP Protection level | IP20 |
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system.
The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.